ADX921AQFN32
-
Two low-noise PGAs and two 24-bit high-resolution ADCs analog ECG front-end
Product details
-
Parameters
-
Characteristics
-
Package
-
Description
-
-
Two PGAs and two 24-bit high-resolution ADCs
-
SPI communication with a sampling rate of 16 Ksps
-
-40°C to +85°C
-
-
-
• Three low-noise (ADX923) PGAs and two high-resolution ADCs (ADX922/3)
8.6μVPP (G = 6)
-
-
-
QFN32 4mm x 4mm
-
-
The ADX920/1/2/3 devices are multichannel, simultaneously sampling, 24-bit, delta-sigma (ΔΣ) analog-to-digital converters (ADCs) with built-in programmable gain amplifiers (PGA), internal reference, and oscillator. The ADX920/1/2/3 devices integrate all the features typically required for portable, low-power medical electrocardiogram (ECG), activity, and fitness applications. With high integration and superior performance, the ADX920/1/2/3 devices enable the creation of scalable medical instrument systems with significantly reduced size, power, and overall cost. Each channel of the ADX920/1/2/3 devices features a flexible input multiplexer that can be independently connected to internally generated signals for testing, temperature, and lead-off detection. Additionally, any input channel configuration can be designated to derive the right leg drive (RLD) output signal. The ADX920/1/2/3 devices operate at data rates up to 8 kSPS. Lead-off detection can be implemented within the device using the internal excitation current sink or source. The ADX922/3 devices include fully integrated respiration impedance measurement functionality. The specified operating temperature range is from –40°C to 85°C.
Related applications
Related products
-
ADX920QAQFN32
Automotive-grade, low-noise PGA and 24-bit high-precision ADC analog ECG front end
-
ADX921QAQFN32
Automotive-grade, two low-noise PGAs and two 24-bit high-precision ADC analog ECG front end
-
ADX922QAQFN32
Automotive-grade integrated respiration impedance, two low-noise PGAs, and two 24-bit high-precision ADCs for an analog ECG front-end.