AFE968AQFP64
-
Low-power, 8-channel, 24-bit ADC with integrated impedance detection for biopotential EEG analog front-end.
Product details
-
Parameters
-
Characteristics
-
Package
-
Description
-
-
BIS, EAP, ECG, ECG, and sleep monitoring devices.
-
8-channel, 24-bit with impedance detection and SPI communication.
-
-40°C to +85°C
-
-
-
• Up to eight low-noise programmable gain amplifiers (PGA) and eight high-resolution simultaneous sampling ADCs.
-
• Input-referred noise
1.7µVPP (65Hz BW)
-
• Input bias current
300pA
-
• Data rate
125SPS 至 32kSPS
-
• Operating modes
• High-speed mode, Low-speed mode, Ultra-low power mode, 8mW
-
• Common Mode Rejection Ratio
-130dB
-
• Programmable gain
1、2、4、6、8、12、24 or 48
-
• Unipolar or bipolar power supply
-
• Built-in bias drive amplifier, AC/DC lead-off detection, test signal
-
• Built-in oscillator
-
• Internal or external reference
-
• VDAC excitation source
-
• Flexible power-down and standby modes
-
• Pin compatible with AFE94x/AFE95x
-
• SPI compatible serial interface (daisy chain)
-
• Operating temperature range
-40°C to+85°C
-
-
-
QFP64 10mm x 10mm
-
BGA64 8mm x 8mm
-
-
The AFE968 device is part of a series of four-channel, six-channel, and eight-channel, low-noise, 24-bit, simultaneous sampling delta-sigma analog-to-digital converters (ADCs). This series integrates programmable gain amplifiers (PGA), internal references, and on-board oscillators, making it particularly suitable for applications such as extra-cranial electroencephalography (EEG) and electrocardiography (ECG). With high integration and outstanding performance, the AFE964/AFE966/AFE968 can significantly reduce size, power consumption, and overall cost, facilitating the development of scalable medical instrument systems. Each channel includes a flexible input multiplexer, enabling independent connection of internally generated signals for testing, temperature, and lead-off detection. Users can also configure any input channel to generate a patient bias output signal. These devices provide a VDAC excitation source, capable of generating both DC and AC excitation signals. The optional SRB pin can be used to route a common signal to multiple inputs for reference configuration. The AFE964/AFE966/AFE968 supports data rates from 125SPS to 32kSPS and can perform lead-off detection using internal excitation current sinks/sources. In multi-channel systems, multiple AFE964, AFE966, or AFE968 devices can be connected in series using a daisy-chain configuration. The devices are available in QFP-64 and BGA-64 packages, with an operating temperature range of –40°C to +85°C.
Related applications
Related products
-
ADX920QAQFN32
Automotive-grade, low-noise PGA and 24-bit high-precision ADC analog ECG front end
-
ADX921QAQFN32
Automotive-grade, two low-noise PGAs and two 24-bit high-precision ADC analog ECG front end
-
ADX922QAQFN32
Automotive-grade integrated respiration impedance, two low-noise PGAs, and two 24-bit high-precision ADCs for an analog ECG front-end.