AFE946AQFP64

  • Low power consumption, 6-channel 24-bit ADC with integrated impedance detection ECG analog front end

Product details

  • Parameters

  • Characteristics

  • Package

  • Description

    • 12-lead, 18-lead ECG monitor

    • 6-channel, 24-bit, SPI communication

    • -40°C to+85°C

    • • 6 low-noise programmable gain amplifiers (PGA) and 6 high-resolution analog-to-digital converters (ADC)

    • • Low power consumption

      0.67mW per channel

    • • Input-referred noise

      6μVPP (150Hz BW,G = 6)

    • • Input bias current

      70pA

    • • Data rate

      125SPS to 64kSPS

    • • Common Mode Rejection Ratio

      -123dB

    • • Programmable gain

      1、2、3、4、6、8、12 or 24

    • • Supports systems compliant with AAMI EC11, EC13, IEC 60601-1, IEC 60601-2-27, and IEC 60601-2-51 standards

    • • Unipolar or bipolar power supply

    • AVDD = 2.7V to 5.5V

    • DVDD = 1.65V to 3.6V

    • • Integrated right leg drive amplifier, lead-off detection, Wilson central terminal, pace detection, and test signal

    • • Integrated voltage-to-digital converter, crystal oscillator, and AC lead stimulation

    • • Digital pace detection feature

    • • Built-in oscillator and reference

    • • Serial Peripheral Interface (SPI™)-compatible serial port, daisy-chain

    • QFP64 10mm x 10mm

    • BGA64 8mm x 8mm

  • The AFE946 is part of a family of multi-channel, synchronous sampling, 24-bit delta-sigma analog-to-digital converters (ADC), featuring integrated programmable gain amplifiers (PGA), internal reference, and an onboard oscillator. The AFE94x series encapsulates all functionalities typically required for medical electrocardiogram (ECG) and electroencephalogram (EEG) applications. With its high level of integration and exceptional performance, the AFE94x enables the development of scalable medical instrument systems with significantly reduced size, power consumption, and overall costs.

    Each channel of the AFE94x includes a versatile input multiplexer (mux) that can independently connect to internally generated signals for testing, temperature, and lead-off detection. Furthermore, any configuration of the input channels can be chosen to generate a right-leg drive (RLD) output signal. The AFE94x operates at data rates up to 64kSPS, facilitating software-based pace detection. Lead-off detection is implemented within the device using pull-up/pull-down resistors or excitation current/sources. Three integrated amplifiers generate the Wilson Central Terminal (WCT) necessary for standard 12-lead ECGs. Multiple AFE94x devices can be daisy-chained in high-channel-count systems.

    Packaging options include QFP-64 and a compact 8mm × 8mm, 64-ball BGA. The AFE94x is rated for a temperature range of -40°C to +85°C.