AFE958ABGA64
-
Low power consumption, 8-channel 24-bit ADC with integrated respiratory impedance bioelectric ECG analog front end
Product details
-
Parameters
-
Characteristics
-
Package
-
Description
-
-
Respiratory impedance detection, 12-lead, 18-lead ECG monito
-
8-channel, 24-bit, SPI communication
-
-40°C to+85°C
-
-
-
• 8 low-noise programmable gain amplifiers (PGA) and 8 high-resolution analog-to-digital converters (ADC)
-
• Operating modes:
-
高速模式(只有 AFE959 有)
-
High-speed mode (only available in AFE959)
-
• Low power consumption
0.76mW per channel
-
Ultra-low power mode (only available in AFE959)
-
• Input-referred noise
4μVPP (150Hz BW,G = 6)
-
• Input bias current
100pA
-
• Data rate
125PS to 64kSPS
-
• Common Mode Rejection Ratio
120dB
-
• Programmable gain
1、2、3、4、6、8、12 or 24
-
• Supports systems compliant with AAMI EC11, EC13, IEC 60601-1, IEC 60601-2-27, and IEC 60601-2-51 standards
-
• Unipolar or bipolar power supply
-
AVDD = 2.7V to 5.5V
-
DVDD = 1.65V to 3.6V
-
IOVDD = 1.65V to 3.6V
-
• Integrated right leg drive amplifier, lead-off detection, Wilson central terminal, pace detection, and test signal
-
• Integrated Respiratory Impedance Measurement Modulation Frequency
32kHz、43kHz、64kHz Independent data rate
-
• Built-in digital conversion voltage, crystal oscillator, and AC lead-off excitation
-
• Built-in oscillator and reference
-
• Serial Peripheral Interface (SPI™)-compatible serial port, daisy-chain
-
-
-
BGA64 8mm x 8mm
-
-
The AFE958 (AFE95x) is a series of multi-channel, simultaneous sampling, 24-bit delta-sigma analog-to-digital converters (ADCs), featuring a programmable gain amplifier (PGA), an internal reference, and an onboard oscillator. The AFE95x integrates all the functions typically required for medical electrocardiogram (ECG) and electroencephalogram applications. With its high level of integration and exceptional performance, the AFE95x enables the development of scalable medical instrumentation systems with significantly reduced size, lower power consumption, and overall cost. Each channel of the AFE95x includes a flexible input multiplexer (MUX) that can independently connect to internally generated signals for testing, temperature monitoring, and lead-off detection. Additionally, the configuration of any input channel can be chosen to generate the right leg drive (RLD) output signal. The AFE95x operates at data rates up to 64kSPS, facilitating software-based pacemaker detection. Lead-off detection can be implemented internally through pull-up/pull-down resistors or excitation current sinks/sources. Three integrated amplifiers are used to generate the Wilson Central Terminal (WCT) required for standard 12-lead ECGs. Multiple AFE95x devices can be connected in a daisy-chain configuration in high-channel-count systems. The device is available in a compact 8mm × 8mm, 64-ball BGA package. The BGA version is rated for industrial temperature ranges from -40°C to +85°C.
Related applications
Related products
-
ADX920QAQFN32
Automotive-grade, low-noise PGA and 24-bit high-precision ADC analog ECG front end
-
ADX921QAQFN32
Automotive-grade, two low-noise PGAs and two 24-bit high-precision ADC analog ECG front end
-
ADX922QAQFN32
Automotive-grade integrated respiration impedance, two low-noise PGAs, and two 24-bit high-precision ADCs for an analog ECG front-end.